logo
Home > products > Oxide Fine Desulfurizer >
Normal Temperature Oxide Fine Desulfurizer Organic Sulfur Conversion And Absorption

Normal Temperature Oxide Fine Desulfurizer Organic Sulfur Conversion And Absorption

Normal Temperature Oxide Fine Desulfurizer

ISO Oxide Fine Desulfurizer

Conversion And Absorption

Place of Origin:

CHINA

Brand Name:

WHATET

Certification:

ISO

Model Number:

WH-104

CONTACT US
Request A Quote
Product Details
Appearance:
Black Stripe
Size:
Ф(3-4)x(3-15)mm
Bulk Density:
0.6±0.1 G/ml
Specific Surface:
>800 M2/g
Capacity:
~0.6 Ml/g
Porosity:
0.41%
Highlight:

Normal Temperature Oxide Fine Desulfurizer

,

ISO Oxide Fine Desulfurizer

,

Conversion And Absorption

Payment & Shipping Terms
Minimum Order Quantity
1T
Price
CN¥250.00 - CN¥550.00
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Product Description

Normal Temperature Organic Sulfur Conversion And Absorption With Oxide Fine Desulfurizer For Removing COS And CS2

 

Application

COS and CS2 are the main organic sulfides in the chemical raw gas produced from coal or heavy oil, and trace amounts of COS and CS2 are the main causes of many catalyst poisoning in the later process. Therefore, how to effectively remove trace amounts of COS and CS2 is a problem that we must solve. COS can be removed by COS hydrolysis catalyst, but it is necessary to set up temperature and cooling equipment, and CS2 is difficult to remove at normal low temperature. WH-104 can make up for the above deficiencies by converting and absorbing organic sulfur at room temperature, and the desulfurizer can not only remove H2S, but also remove COS and CS2 at room temperature.

 

Technical indicators  (the sulfur capacity in the table refers to the working sulfur capacity or penetrating sulfur capacity)

 

Desulfurization form H2S COS CS2
Weight Sulfur Capacity % ≥12 ≥3 ≥4

 

Terms of use

WH-104 organic sulfur conversion and absorption refined desulfurizer at room temperature should be used in tandem with activated carbon refined desulfurizer or iron oxide refined desulfurizer, and activated carbon or iron oxide refined desulfurizer should be placed in front to check H2S.

1. Airspeed

COS,CS2 <2mg/m3 airspeed:1000—2000h-1
COS,CS2>2mg/m3 airspeed:500—1000h-1

2. Tem0—60℃.
3. Compressive stress:normal-10MPa
4. Humidity: The higher the humidity, the better, preferably close to saturated water vapor, but not liquid water.

 

Send your inquiry directly to us

Privacy Policy China Good Quality Lignosulfonate Supplier. Copyright © 2024-2025 Wuhan Anji Taineng Environmental Sci-Tech Co., Ltd . All Rights Reserved.