Heater temperature
Q1: How many degrees can the heating be added?
A1: Under normal circumstances, in the biological fermentation industry, the temperature heating in summer is between 45 degrees and 55 degrees, and the temperature heating in winter is between 40 degrees and 50 degrees. In special cases, we can adjust the performance of the cooler through the program
Q2: What is the effect of the Air Cooler?
A2: The system's cooler contains two stages of cooling, cooling water is used in summer, and low temperature circulating water can be used in winter, so as to reach the dew point temperature (18~20 degrees) for water removal.
Dew point temperature: the critical value of gas into liquid dehumidification effect
Q3: How is your water removal effect?
A3: The whole system is divided into three levels of water removal, the water removal rate is as high as 99.99%.
The first stage, when the compressed air drops to the dew point temperature, the large particles of water droplets separate out through the hole plate of the cooler;
At the second stage, the cold air passes through the guide plate, using the role of centrifugal force to discharge the water molecules in the air;
In the third season, the condensed water in the form of mist is captured when passing through the encrypted mesh separator, achieving a separation efficiency of 99.99%.
Pressure Drop
Q4: Why can your pressure drop achieve 5kpa?
A4: The system is composed of three devices: heater cooler gas-liquid separator The cooler adopts a single flow layer structure, the air is not deflected the heater adopts optical tube spiral deflected, which reduces the pressure loss than the single tube fin 13. The mesh fogging device in the gas-liquid separator uses a special stainless steel wire with uniform microholes, and the pressure loss is only 16 of the traditional gas, less than 2kpa